Power Knowledge | The "Earthquake" in the Power System: Forced Oscillation and Its Control Strategies
The power system is composed of various power equipment and lines, and forced oscillation may occur due to the mismatch of frequency characteristics of equipment or lines. Its inducing factors include the mismatch of equipment parameters, the instability of equipment, or errors in the control strategy. Forced oscillation will lead to the instability and even collapse of the power system, causing changes in voltage and frequency, damaging equipment, and affecting other equipment in the system. To solve this problem, common control strategies include phase angle compensation, which stabilizes the system by controlling the phase angle difference between the generator and the load and adjusting the generator excitation; dynamic damping, which increases the system damping ratio by controlling the generator excitation and the voltage regulator and uses a computer system to monitor and adjust in real time; frequency regulation control, which adjusts the frequency according to the system frequency and the generator output; and multi-machine coordination control, which maintains the system stability by coordinating the excitation and load distribution of multiple generators. Adopting these control strategies can reduce forced oscillation and improve the stability and reliability of the power system.
2025 04 17
Power Knowledge | What is Intelligent Power Operation and Maintenance? What are Its Advantages?

Equipment inspection and maintenance is crucial for ensuring the safe and stable operation of power equipment, and it has now moved towards intelligence. Intelligent power operation and maintenance relies on advanced technologies such as computer Internet and big data processing. It integrates power equipment condition detection technology and various online detection data, and constructs an intelligent operation and maintenance system for power equipment conditions based on a big data platform and with the Internet of Things as the link. Its management system can collect substation data in real time, and when there are abnormalities, it will promptly feedback and notify engineers to judge faults and guide operations. This business is widely applied in scenarios such as equipment, personnel, inspection, maintenance, fault, dynamic environment, security, and power control. It has significant advantages, including improving the utilization rate of production resources, realizing unmanned or minimally manned operation in distribution rooms based on energy efficiency big data; having a fault alarm function, predicting potential faults in advance through big data analysis; and using big data and Internet of Things technology to remotely, centrally, and real-timely monitor distribution rooms, saving labor costs and reducing the work pressure of operation and maintenance personnel.
2025 04 16
Conocimiento de la energía | Tecnología de detección de descargas parciales en transformadores y su aplicación

La descarga parcial (PD) es uno de los factores clave que provocan el envejecimiento del aislamiento durante el funcionamiento a largo plazo de los transformadores. Este artículo presenta principalmente la definición, los peligros y los métodos de detección de descargas parciales, y explora las aplicaciones importantes de la detección de descargas parciales en el mantenimiento de transformadores y el diagnóstico de fallas.
2025 04 15
Conocimiento del Poder | El Problema de la Saturación Magnética del Transformador y sus Soluciones

Este artículo se centra en el problema de la saturación magnética del transformador. En primer lugar, señala que la saturación magnética es un problema común durante el funcionamiento del transformador. Luego explica su principio, es decir, el transformador se basa en la inducción electromagnética y la densidad de flujo magnético del núcleo magnético cambia con la fuente de alimentación de corriente alterna. Una vez que alcanza un determinado valor, el núcleo magnético entra en el estado de saturación magnética. Luego explica que la saturación magnética traerá consigo problemas como altas corrientes armónicas que causan problemas de calidad de energía, sobrecalentamiento del equipo que acorta su vida útil y mal funcionamiento de los dispositivos de protección que conducen a inestabilidad dinámica. En respuesta a estos problemas, las soluciones propuestas cubren aspectos como la selección de materiales de núcleo magnético apropiados, garantizar una relación de vueltas apropiada, una gestión de carga razonable, instalar supresores de saturación magnética, fortalecer el monitoreo y la protección, realizar mantenimiento y revisiones regulares y optimizar el diseño, a fin de garantizar el funcionamiento seguro y estable del transformador.
2025 04 14
Power Knowledge | Comparative Analysis of Oil-immersed Transformers and Dry-type Transformers

This article makes a comparative analysis of oil-immersed transformers and dry-type transformers. It expounds on the working principles of the two. The oil-immersed transformer relies on insulating oil for cooling and insulation, while the dry-type transformer uses natural air cooling or forced air cooling for heat dissipation. The advantages of the oil-immersed transformer are high heat capacity, high electrical strength, and low cost, while the disadvantages are easy leakage, regular maintenance required, and flammability. The dry-type transformer has the advantages of environmental friendliness, safety, and easy maintenance, but its disadvantages are weak heat dissipation, high cost, and high noise. The oil-immersed transformer is suitable for high-voltage and large-capacity scenarios, and the dry-type transformer is suitable for densely populated areas and places with high environmental protection requirements. In terms of performance, there are differences in heat dissipation, cost, safety, and environmental friendliness between the two. In terms of technological development, the oil-immersed transformer is researching and developing biodegradable insulating oil and optimizing the design, and the dry-type transformer is studying new heat dissipation materials and noise reduction technologies. In short, the two have different characteristics, and when making a choice, multiple factors need to be comprehensively considered, and attention should be paid to new technologies.
2025 04 11
Conocimiento de Energía | ¿Qué inspecciones especiales deben tenerse en cuenta durante la inspección de equipos de subestaciones?

Esta divulgación del conocimiento energético se centra en la inspección de los equipos de las subestaciones, haciendo hincapié en su importancia para la gestión de la operación de los equipos. Además de las inspecciones regulares, detalla varias situaciones en las que se requieren inspecciones especiales de los transformadores, como dentro de las 72 horas posteriores a la puesta en funcionamiento de equipos nuevos o transformadores renovados, en caso de defectos graves, sobrecarga, durante períodos de alta temperatura y carga máxima, en la temporada de tormentas eléctricas (especialmente después de tormentas eléctricas), en días ventosos, en días de tormenta eléctrica y niebla, durante vacaciones y períodos especiales de garantía de suministro de energía, etc. También presenta el Monitoreo en línea del desempeño general del transformador EDS MK3, explicando en detalle sus funciones de diagnóstico, incluyendo corriente de línea, temperatura del núcleo de hierro y devanados, humedad en el aceite aislante, ciclo de vida del transformador, cambiador de tomas en carga y diagnóstico del sistema de enfriamiento, lo que ayuda a inspeccionar mejor el transformador.
2025 04 10
Installation Standards and Operation Procedures of Distribution Transformers

This document elaborates in detail on the installation standards and operation procedures of distribution transformers. First, the formalities for work approval and acceptance of construction tasks need to be completed, with written approval from the competent department. Then, on-site investigation is carried out by the on-site construction leader and technicians. They record relevant information, determine hazard points and control measures, and formulate a construction plan. Before construction, a pre-shift meeting should be held. The work leader needs to conduct a technical disclosure, explaining the construction plan, process quality requirements, and precautions. Meanwhile, a safety disclosure is carried out, clarifying hazard points such as prevention of falling from heights, electric pole collapse and injury, falling objects from heights causing injury, and the transformer falling or collapsing and causing injury, as well as corresponding control measures. Finally, work tasks are assigned and personnel are divided.
2025 04 09
Uso del transformador de prueba de tipo seco GTB

Este artículo proporciona una introducción detallada al transformador de prueba de tipo seco GTB. Cubre aspectos tales como sus características en el diseño de la estructura de aislamiento, soluciones a problemas de fugas de aceite, manejo del extremo de salida de alto voltaje, diseño del tanque de aceite y la estructura del núcleo de hierro y las bobinas. Se explica el propósito de este transformador al generar altos voltajes de CA y CC para la detección in situ del rendimiento de aislamiento de varios equipos eléctricos, se enumeran sus numerosos nombres alternativos y se brindan métodos de uso detallados, incluidas las preparaciones antes del uso, la conexión de energía, la composición del conjunto completo de equipos, las operaciones para pruebas de CC y las precauciones para la conexión en cascada. También enfatiza que sigue estrictamente los estándares pertinentes para garantizar la seguridad.
2025 04 08
15 Fundamental Questions about Power Transformers

This article focuses on 15 fundamental issues of power transformers, covering key areas such as the grounding of the transformer core, gas protection, and the handling of cooler failures. It elaborates in detail on aspects like the conditions for parallel operation of transformers, the causes of abnormal noises, and the adjustment limitations of the tap changers of on-load tap changer devices. It also involves knowledge points such as methods to improve the efficiency of transformers and the influencing factors of transformer capacity. By answering these questions, it systematically sorts out the basic knowledge of the operation and maintenance of power transformers for readers.
2025 04 07
El proceso paso a paso de la solución de escaneo láser 3D para subestaciones

La tecnología de escaneo láser 3D, con su método de medición de alta velocidad sin contacto, puede obtener de manera eficiente datos relevantes del terreno y objetos complejos. Después del procesamiento, puede construir modelos 3D y también se conoce como tecnología de replicación de escenas reales.

La solución de escaneo láser 3D para subestaciones consta de los siguientes pasos. Incluye el análisis de los requisitos de medición, aclarando el área de escaneo, la precisión y el método de acuerdo con la situación real de la subestación. Durante la medición in situ, se debe prestar atención a la selección, el diseño y la depuración del equipo de escaneo. El procesamiento de datos implica operaciones como limpieza y registro para generar modelos 3D. La verificación del modelo garantiza la precisión e integridad de los datos. Finalmente, el modelo se aplica a diversos aspectos de la gestión de operación y mantenimiento de la subestación.

Cabe señalar que esta solución debe diseñarse y ajustarse en combinación con factores como las condiciones del sitio, los requisitos de seguridad y la precisión de la medición, y se requiere tecnología y equipos profesionales para garantizar la calidad de los datos.
2025 04 03
Mantenimiento diario de transformadores

Los transformadores son de gran importancia en la red de distribución y sus condiciones de funcionamiento tienen un impacto de gran alcance. Este artículo se centra en el mantenimiento diario de los transformadores, abarcando dos aspectos principales.

Lo primero es reforzar las inspecciones diarias, el mantenimiento y las pruebas periódicas. Esto incluye verificar la apariencia para detectar fugas de aceite, escuchar el sonido para identificar fallas, limpiar manchas de aceite y polvo, observar el color y la temperatura del aceite, medir la resistencia del aislamiento, medir y equilibrar la carga y verificar y reemplazar regularmente los fusibles.

El segundo es prevenir daños externos, lo que implica una selección razonable del sitio, evitar la instalación de cajas de medición de bajo voltaje, prohibir el ajuste no autorizado de cambiadores de tomas, instalar cubiertas de aislamiento e inspeccionar regularmente las líneas y cortar derivaciones a lo largo de los canales de las líneas. Todas estas medidas tienen como objetivo garantizar el funcionamiento seguro y estable de los transformadores.
2025 04 02
Power Classroom | Maintenance and Fault Repair Methods of Transformers

Transformers play a crucial role in the power system, and their operating status is directly related to the stability of power supply. This content focuses on the maintenance and fault repair methods of transformers. Firstly, it introduces the basic principles, components, functions, and common classifications of transformers.

Then, it elaborates on the key points of maintenance: In terms of capacity, the normal operating load should preferably be 75 - 90% of the rated capacity. The temperature needs to be recorded regularly, and the three-phase load of distribution transformers should be paid attention to during the period of maximum load. For insulation monitoring, the insulation resistance of the coils should be measured after installation, maintenance, and long-term outages. In terms of the current range, the maximum unbalanced current on the low-voltage side should not exceed 25% of the rated value, and the change in the power supply voltage should be within ±5% of the rated value. If it exceeds this range, a tap changer should be used for adjustment. In the case of overload, it is allowed for a short time under special circumstances, but there are different limits for winter and summer.

Finally, it explains the fault repair. Common faults include short circuits, open circuits, and leakage, which are caused by design errors, poor manufacturing quality, and exceeding the designed operating conditions. The repair steps are to disassemble the iron core, heat it to melt the poured materials, and carefully remove the silicon steel sheets. Then, disassemble the coils, inspect the appearance and the faulty coil, record key data, deal with the fault, rewind it according to the original method, and conduct a comprehensive test. It can be put back into use only after passing the test.
2025 04 01
sin datos
recommended for you
sin datos

Shengzhi Electric Power is a comprehensive power service enterprise that integrates the research and development, design, manufacturing, sales, and after-sales of power equipment.

Contact Us

Contact: Shawn kou

Tel: +8613001234440

Email: Shawnkou@hnszrn.com

WhatsApp: +8613001234440

Company address: No. 29 Jintian Road, Zhongyuan District, Zhengzhou City, Henan Province

Copyright © 2025 Henan Shengzhi Ruinuo Electrical Equipment Co., Ltd. | Mapa del sitio    |   política de privacidad
Customer service
detect